Fast GC analysis of THT and TBM in natural gas in under two minutes using an Agilent J&W Lowox column.
- Publication Part Number: A02248
- Created: 31 Oct 2011
- 820 KB
| Publication Part Number | A02248 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Fast GC analysis THT and MES in natural gas in three minutes, using an Agilent J&W Lowox column.
- Publication Part Number: A02249
- Created: 31 Oct 2011
- 823 KB
| Publication Part Number | A02249 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates three sulfur contaminants in natural gas in less than ten minutes.
- Publication Part Number: A01625
- Created: 31 Oct 2011
- 308 KB
| Publication Part Number | A01625 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 5 CB UltiMetal column separates sulfur compounds in natural gas in eight minutes.
- Publication Part Number: A01296
- Created: 31 Oct 2011
- 597 KB
| Publication Part Number | A01296 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 19 CB for THT column module and Agilent 490 Micro GC separates tetrahydrothiophene in natural gas in 75 seconds.
- Publication Part Number: A01239
- Created: 31 Oct 2011
- 363 KB
| Publication Part Number | A01239 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-SilicaPLOT column analyzes ethanethiol in a sample of liquid petroleum gas in four minutes.
- Publication Part Number: A01452
- Created: 31 Oct 2011
- 536 KB
| Publication Part Number | A01452 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Molsieve 5? column module and Agilent 490 Micro GC and a special column module determines 1-butyl mercaptane (TBM) in natural gas in
- Publication Part Number: A01236
- Created: 31 Oct 2011
- 320 KB
| Publication Part Number | A01236 | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Application note for the analysis of Low-Level Sulfur Compounds in Natural Gas and Propylene Using a Pulsed Flame Photometric Detector
- Publication Part Number: 5990-9215EN
- Created: 20 Oct 2011
- 1 MB
| Publication Part Number | 5990-9215EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|