The seamless transfer of the EPA method (8330A/B) from the Agilent 1200 Series Rapid Resolution LC (RRLC) to the Agilent 1290 Infinity Binary LC using ISET is demonstrated
- Publication Part Number: 5991-1194EN
- Created: 15 Sep 2014
- 873 KB
| Publication Part Number | 5991-1194EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Poroshell 120 PFP gives extra retention and selectivity of halogenate positional isomers, enhanced with functional groups on aromatic or other rigid ring systems.
- Publication Part Number: 5991-4373EN
- Created: 03 Apr 2014
- 306 KB
| Publication Part Number | 5991-4373EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Separation of 19 nitro-aromatics using automated consecutive injections on two columns with different separation mechanism.
- Publication Part Number: 5991-3212EN
- Created: 01 Oct 2013
- 5 MB
| Publication Part Number | 5991-3212EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
The EPA 8330A analysis of nitroaromatics and nitramines explosive residues was improved by using a Poroshell 120 EC-CN column for confirmation and a Poroshell 120 EC-C18
- Publication Part Number: 5991-1682EN
- Created: 20 Dec 2012
- 542 KB
| Publication Part Number | 5991-1682EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Nitro aromatics and cyclic ketones are analyzed by GC according to EPA 8090 using the stabilized 50% phenyl PDMS phase of Agilent J&W VF-17ms.
- Publication Part Number: A02285
- Created: 31 Oct 2011
- 700 KB
| Publication Part Number | A02285 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 120 semivolatiles according to EPA 8270 in 94 minutes.
- Publication Part Number: A0805
- Created: 31 Oct 2011
- 2 MB
| Publication Part Number | A00805 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC separation of 13 nitro and sulfur compounds according to EPA 8270 is achieved in 20 minutes with an J&W Agilent VF-17ms column.
- Publication Part Number: A02279
- Created: 31 Oct 2011
- 965 KB
| Publication Part Number | A02279 | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
GC/MS analysis of eight nitroaromatics and cyclic ketones according to EPA 8090, with an Agilent J&W VF-200ms column, is achieved in less than 20 minutes.
- Publication Part Number: A02097
- Created: 31 Oct 2011
- 427 KB
| Publication Part Number | A02097 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates nine nitroaromatics and cyclic ketones according to EPA 8090 in 33 minutes.
- Publication Part Number: A0800
- Created: 31 Oct 2011
- 548 KB
| Publication Part Number | A00800 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Using GC/MS, an Agilent J&W VF-200ms column separates 13base neutrals according to EPA8270 in 20 minutes.
- Publication Part Number: A2090
- Created: 31 Oct 2011
- 503 KB
| Publication Part Number | A02090 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Describes the analysis of 14 compounds for U.S. EPA 8330 explosives at subng/mL levels in soil samples with LC. Low detection limits of 5 ppb (μg/kg) were obtained.
- Publication Part Number: 5990-6871EN
- Created: 01 Dec 2010
- 650 KB
| Publication Part Number | 5990-6871EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
487B.jpg
- Publication Part Number: 880975-302
- Created: 08 May 2018
- 44 KB
- JPG
| Publication Part Number | 487B | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
487A_024168.jpg
- Created: 08 May 2018
- 49 KB
- JPG
| Publication Part Number | 487A | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
通過(guò)將 Agilent 1290 Infinity 液相色譜系統(tǒng)與 Agilent 6460 三重四極桿 LC/MS 系統(tǒng)聯(lián)用,采用 HPLC 將用于分析水中痕量爆炸物的 EPA 8330B 方法中從紫外檢測(cè)到質(zhì)譜檢測(cè)的轉(zhuǎn)移中
- Publication Part Number: 5991-0676CHCN
- Created: 27 June 2012
- 501 KB
| Publication Part Number | 5991-0676EN | ||||||
|---|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||||
| Instrument |
|
||||||
| Analytical Technique | Technique |
|
|||||
| Injection |
|
||||||
| Detection |
|
||||||
| Sample | Chemical Group |
|
|||||
| Sample Matrix |
|
Agilent ACE Partner Edition
- Publication Part Number: 5991-2981KO
- Created: 13 Dec 2013
- 1 MB
| Publication Part Number | 5991-2981EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
| French (France) | Complete (PDF) |
|---|---|
| Portuguese (Brazil) | Complete (PDF) |
| German (Germany) | Complete (PDF) |
| Spanish (Spain) | Complete (PDF) |
| Italian (Italy) | Complete (PDF) |