Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
- Chemical Group
-
- Injection Technique
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
FID detection fatty acid methyl esters (FAME) on a CP-Sil 88 for FAME GC column.
- Publication Part Number: SI-02178
- Created: 10 Nov 2015
- 133 KB
| Publication Part Number | SI-02178 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Application note for the GC analysis of 37 FAME Component Mixture using CP-Select for FAME Column
- Publication Part Number: SI-2164
- Created: 30 Jan 2014
- 169 KB
| Publication Part Number | SI-02164 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC with an Agilent J&W CP-Sil 88 for FAME column separates 13 C16 to C24 fatty acids of polar glycerolipids and minor lipids from green algae in 30 minutes.
- Publication Part Number: A01525
- Created: 31 Oct 2011
- 426 KB
| Publication Part Number | A01525 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 88 for FAME column separates 19 fatty acid methyl esters in 20 minutes.
- Publication Part Number: A00091
- Created: 31 Oct 2011
- 629 KB
| Publication Part Number | A00091 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 26 fatty acid methyl esters in 75 minutes.
- Publication Part Number: A0266
- Created: 31 Oct 2011
- 557 KB
| Publication Part Number | A00266 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 33 C10 to C22 fatty acid methyl esters in Russian fish oil in 54 minutes.
- Publication Part Number: A0475
- Created: 31 Oct 2011
- 660 KB
| Publication Part Number | A00475 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 27 C11 to C20 fatty acid methyl esters in 20 minutes.
- Publication Part Number: A0365
- Created: 31 Oct 2011
- 994 KB
| Publication Part Number | A00365 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 88 for FAME column separates 24 C14 to C24 fatty acid methyl esters in a lipid extract from rat heart in 16 minutes.
- Publication Part Number: A0472
- Created: 31 Oct 2011
- 720 KB
| Publication Part Number | A00472 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 21 C12 to C24 fatty acid methyl esters in fish oil in 20 minutes.
- Publication Part Number: A0169
- Created: 31 Oct 2011
- 547 KB
| Publication Part Number | A00169 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates nine residual solvents in a sample of video tape in 70 minutes.
- Publication Part Number: A1047
- Created: 31 Oct 2011
- 673 KB
| Publication Part Number | A01047 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 23 C10 to C18 fatty acid methyl esters in ox fat in 28 minutes.
- Publication Part Number: A0474
- Created: 31 Oct 2011
- 677 KB
| Publication Part Number | A00474 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 24 C8 to C24 fatty acid methyl esters in fish oil in 14 minutes.
- Publication Part Number: A0471
- Created: 31 Oct 2011
- 711 KB
| Publication Part Number | A00471 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 32 C4 to C20 fatty acid methyl esters in butter oil in 36 minutes.
- Publication Part Number: A0470
- Created: 31 Oct 2011
- 827 KB
| Publication Part Number | A00470 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Select CB for Fame column separates 19 fatty acid methyl esters in under 60 minutes.
- Publication Part Number: A01911
- Created: 01 Oct 2011
- 769 KB
| Publication Part Number | A01911 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Application note for the analysis of fatty acids in Infant Formulas Using a J&W HP-88 Capillary GC Column
- Publication Part Number: 5990-8429EN
- Created: 17 June 2011
- 426 KB
| Publication Part Number | 5990-8429EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
| Japanese (Japan) | Complete (PDF) |
|---|
Agilent 7820 GC システムを使用した脂肪酸分析ソリューション
- Publication Part Number: 5991-2482JAJP
- Created: 23 July 2013
- 3 MB
| Publication Part Number | 5991-2482EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|