Refine Results
- Products
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
- Injection Technique
-
- Instrument
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
The Agilent Inert Flow Path outperformed a non-Agilent version for trace pesticides, with less impact on analytes and better results for some critical pesticides.
- Publication Part Number: 5991-3234EN
- Created: 19 Sep 2013
- 925 KB
| Publication Part Number | 5991-3234EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Flow path inertness is critical in pesticide analysis accuracy and precision, especially for active analytes such as organophosphate pesticides.
- Publication Part Number: 5991-1860EN
- Created: 13 Mar 2013
- 1 MB
| Publication Part Number | 5991-1860EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Russian (Russia) | Complete (PDF) |
|---|
A GC/MS/MS method for the analysis of pesticide residues in fruits and vegetables was developed, optimized, and successfully implemented
- Publication Part Number: 5991-1054EN
- Created: 11 Oct 2012
- 641 KB
| Publication Part Number | 5991-1054EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
| Korean (Korea) | Complete (PDF) |
|---|
Application note for a Blind Study of Pesticides in Vegetables by Bond Elut QuEChERS Extraction Kits and Agilent 5975T LTM GC/MSD
- Publication Part Number: 5990-6323EN
- Created: 06 Jan 2012
- 121 KB
| Publication Part Number | 5990-6323EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
The Agilent J&W VF-5ms GC column separates 51 pesticide residues in vegetable samples in 38 minutes.
- Publication Part Number: A02441
- Created: 11 May 2010
- 671 KB
| Publication Part Number | A02441 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
A method has been developed using Agilent 5977A GC/MSD that can deliver excellent linearity, reproducibility, and sensitivity for 42 pesticides commonly analyzed in China.
- Publication Part Number: 5991-2212RU
- Created: 28 Sep 2015
- 86 KB
| Publication Part Number | 5991-2212EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
本文介紹了包含300 多種農(nóng)藥的觸發(fā)式MRM數(shù)據(jù)庫和譜庫的開發(fā),并應(yīng)用于采用 120 種特定農(nóng)藥殘留開發(fā)的LC/MS 方法分析多種食品。
- Publication Part Number: 5991-1183CHCN
- Created: 20 June 2013
- 844 KB
| Publication Part Number | 5991-1183EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|