Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Compounds
-
Compounds
- Injection Technique
- Language
-
Language
Applied Filters
Gas chromatography with an Agilent J&W CP-Wax 52 CB column identifies thiophene in a benzene sample in less than 15 minutes.
- Publication Part Number: A01350
- Created: 31 Oct 2011
- 844 KB
| Publication Part Number | A01350 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-SimDist Ultimetal column separates 13 C12 to C60 waxes plus a sulfur standard in 16 minutes.
- Publication Part Number: A00589
- Created: 31 Oct 2011
- 501 KB
| Publication Part Number | A00589 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 14 sulfur compounds in a hydrocarbon matrix by selective detection in 13 minutes.
- Publication Part Number: A01349
- Created: 31 Oct 2011
- 812 KB
| Publication Part Number | A01349 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Sil 5 CB for Sulfur column separates four sulfur compounds in ten minutes.
- Publication Part Number: A01258
- Created: 31 Oct 2011
- 369 KB
| Publication Part Number | A01258 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Sil 5 CB UltiMetal column separates sulfur compounds in natural gas in eight minutes.
- Publication Part Number: A01296
- Created: 31 Oct 2011
- 597 KB
| Publication Part Number | A01296 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Boiling point analysis of sulfur compounds in kerosene (jet fuel) by gas chromatography is achieved using an Agilent J&W CP-Sil 5 CB column in ten minutes.
- Publication Part Number: A01813
- Created: 01 Oct 2011
- 1 MB
| Publication Part Number | A01813 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|