Refine Results
- Products
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Chemical Group
-
- Instrument
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Gas chromatography with an Agilent J&W CP-WAX 57 CB column provides a unique selectivity in the analysis of 20 impurities in a whisky in 37 minutes.
- Publication Part Number: A01539
- Created: 30 Nov 2015
- 1 MB
| Publication Part Number | A01539 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC with an Agilent J&W CP-Wax 57 CB column delivers excellent selectivity in the analysis of 25 impurities in an alcoholic beverage in 37 minutes.
- Publication Part Number: A01540
- Created: 30 Nov 2015
- 1 MB
| Publication Part Number | A01540 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
An Agilent J&W DB-624UI column was compared with non-Agilent 624 phases, delivering better performance for C3 through C8 volatiles.
- Publication Part Number: 5991-1441EN
- Created: 08 Nov 2012
- 622 KB
| Publication Part Number | 5991-1441EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
The inertness of Agilent J&W DB-624UI gives excellent peak shape and sensitivity for active aldehydes and organic acids in complex beer matrices, for straightforward profiling
- Publication Part Number: 5991-1136EN
- Created: 08 Oct 2012
- 978 KB
| Publication Part Number | 5991-1136EN | ||||||
|---|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||||
| Instrument |
|
||||||
| Analytical Technique | Technique |
|
|||||
| Injection |
|
||||||
| Detection |
|
||||||
| Sample | Chemical Group |
|
|||||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
J&W DB-624 Ultra Inert Capillary Column Screens Distilled Spirits by GC/MS Static Headspace
- Publication Part Number: 5991-0659EN
- Created: 07 June 2012
- 860 KB
| Publication Part Number | 5991-0659EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
| Russian (Russia) | Complete (PDF) |
|---|
Gas chromatography with an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separates 21 alcohols and esters in ‘fire water’ in 21 minutes.
- Publication Part Number: A0619
- Created: 31 Oct 2011
- 854 KB
| Publication Part Number | A00619 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separates butanols in wine in seven minutes.
- Publication Part Number: A0693
- Created: 31 Oct 2011
- 537 KB
| Publication Part Number | A00693 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|