Refine Results
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Compounds
-
Compounds
- Language
-
Language
Applied Filters
Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates ten impurities in propylene in 14 minutes.
- Publication Part Number: A0714
- Created: 31 Oct 2011
- 601 KB
| Publication Part Number | A00714 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC with Agilent J&W CP-Al2O3/KCl separates C2 to C4 hydrocarbons in a light hydrocarbon stream in 15 minutes, with complete separation at elevated temperature.
- Publication Part Number: A01511
- Created: 31 Oct 2011
- 1 MB
| Publication Part Number | A01511 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography using an Agilent J&W CP-Al2O3/KCl column identifies six C2 to C4 hydrocarbon impurities in vinylchloride in 15 minutes.
- Publication Part Number: A0270
- Created: 31 Oct 2011
- 362 KB
| Publication Part Number | A00270 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC with an Agilent J&W CP-Al2O3/Na2SO4 column separates C2 to C4 hydrocarbons in a light hydrocarbon stream in 27 minutes, with complete separation at elevated temperature.
- Publication Part Number: A01512
- Created: 31 Oct 2011
- 840 KB
| Publication Part Number | A01512 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-AL2O3/Na2SO4 column separates impurities in light hydrocarbon streams such as ethylene in eight minutes.
- Publication Part Number: A01514
- Created: 31 Oct 2011
- 474 KB
| Publication Part Number | A01514 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-AL2O3/Na2SO4 column separates butenes in a butane stream in 22 minutes.
- Publication Part Number: A01513
- Created: 31 Oct 2011
- 646 KB
| Publication Part Number | A01513 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|