Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Chemical Group
- Language
-
Language
Applied Filters
Gas chromatography with an Agilent J&W PoraPLOT Q column separates 11 chlorofluorocarbons using valve injection in 15 minutes.
- Publication Part Number: A00660
- Created: 31 Oct 2011
- 527 KB
| Publication Part Number | A00660 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates a standard mix of 10 chlorofluorohydrocarbons in 20 minutes.
- Publication Part Number: A01351
- Created: 31 Oct 2011
- 813 KB
| Publication Part Number | A01351 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W PoraPLOT Q column separates 11 chlorofluorocarbons using valve injection in 15 minutes.
- Publication Part Number: A0659
- Created: 31 Oct 2011
- 601 KB
| Publication Part Number | A00659 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates three chlorofluorocarbons and methane in six minutes.
- Publication Part Number: A01259
- Created: 31 Oct 2011
- 447 KB
| Publication Part Number | A01259 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W PoraPLOT Q column separates 15 chlorofluorocarbons in 25 minutes.
- Publication Part Number: A01110
- Created: 31 Oct 2011
- 529 KB
| Publication Part Number | A01110 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight chlorofluorocarbons in six minutes.
- Publication Part Number: A0918
- Created: 31 Oct 2011
- 570 KB
| Publication Part Number | A00918 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Fast GC analysis of halogenated refrigerant mixtures is achieved in less than 50 seconds using an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC.
- Publication Part Number: A01957
- Created: 31 Oct 2011
- 564 KB
| Publication Part Number | A01957 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|