Refine Results
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Compounds
-
Compounds
- Detection Technique
- Injection Technique
- Instrument
- Language
-
Language
Applied Filters
A method has been developed on the Agilent 5977A Series GC/MSD System that can provide detection of N-nitrosamines in water at sub-part per trillion (ppt) levels
- Publication Part Number: 5991-1970EN
- Created: 12 Feb 2013
- 81 KB
| Publication Part Number | 5991-1970EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Japanese (Japan) | Complete (PDF) |
|---|
GC analysis of nine EPA 8270 nitrosamines on a 0.53 mm wide-bore Agilent J&W VF-5ms capillary column takes only 20 minutes.
- Publication Part Number: A02252
- Created: 31 Oct 2011
- 865 KB
| Publication Part Number | A02252 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Using GC/MS, an Agilent J&W VF-200ms column separates nine nitrosamines according to EPA8270 in less than 20 minutes.
- Publication Part Number: A02091
- Created: 31 Oct 2011
- 402 KB
| Publication Part Number | A02091 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
GC separation of nine nitrosamines according to EPA 8270 is achieved in under 20 minutes with the stabilized 50% phenyl PDMS phase in an Agilent VF-17ms column.
- Publication Part Number: A02278
- Created: 31 Oct 2011
- 786 KB
| Publication Part Number | A02278 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC analysis of nitrosamines according to EPA 8270 uses the stabilized 50% phenyl PDMS of an Agilent J&W VF-17ms column.
- Publication Part Number: A02296
- Created: 31 Oct 2011
- 702 KB
| Publication Part Number | A02296 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Gas chromatography with an Agilent J&W CP-Wax 51 for Amines column separates nine nitrosamines according to EPA 607 in 18 minutes.
- Publication Part Number: A0785
- Created: 31 Oct 2011
- 493 KB
| Publication Part Number | A00785 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
GC separation of 13 basic aromatic compounds uses the stabilized 50% phenyl PDMS phase of an Agilent VF-17ms column.
- Publication Part Number: A02277
- Created: 31 Oct 2011
- 690 KB
| Publication Part Number | A02277 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Separation of nine nitrosamines using Agilent J&W VF-1701ms in 20 minutes.
- Publication Part Number: A02383
- Created: 11 May 2010
- 759 KB
| Publication Part Number | A02383 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Agilent J&W VF-1701ms columns separate 14 base neutrals in 37 minutes.
- Publication Part Number: A02386
- Created: 11 May 2010
- 712 KB
| Publication Part Number | A02386 | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Analysis of nine nitrosamines by gas chromatography using an Agilent J&W VF-1301ms column in 22 minutes.
- Publication Part Number: A02416
- Created: 11 May 2010
- 627 KB
| Publication Part Number | A02416 | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
利用創(chuàng)新型安捷倫微吸附采樣器(CTS)、熱分離進(jìn)樣桿(TSP) 和Agilent 5975T 低熱容氣 質(zhì)聯(lián)用儀(LTM GC/MS) 建立一種測(cè)定環(huán)境氣體中亞硝胺類化合物的方法。
- Publication Part Number: 5991-1554CHCN
- Created: 08 July 2013
- 275 KB
| Publication Part Number | 5991-1554EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|