Refine Results
- Products
- Content Type
-
Content Type
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
Evaluating 209 PCBs congeners by GC/MS using the Agilent 8890/5977C GC/MSD equipped with the Agilent HydroInert ion source and Agilent J&W DB-XLB column.
- Publication Part Number: 5994-8541EN
- Created: 22 Aug 2025
- 631 KB
Meet the Agilent 7000E and 7010C triple quadrupole GC/MS systems. The 7000E provides robust, day-in, day-out performance, while the 7010C is designed for analyses that demand the lowest limits of detection.
- Publication Part Number: 5994-4921EN
- Created: 29 July 2025
- 23 MB
Ethylene oxide (EO) and 1,4-dioxane are critical industrial chemicals often found as residuals in surfactant production.
- Publication Part Number: 5994-8335EN
- Created: 18 July 2025
- 534 KB
This manual contains information for operating and maintaining the Agilent JetClean System.
- Publication Part Number: G7077-90052
- Created: 01 Oct 2024
- 1 MB
The benefits of hydrogen in gas chromatography (GC) are widely accepted - it can be generated in the lab in a cost-effective manner, and it produces fast chromatography and higher sample throughput.
- Publication Part Number: 5994-7680EN
- Created: 06 Aug 2024
- 278 KB
This application note shows the analysis of phthalate with hydrogen carrier gas using the Agilent HydroInert source on a challenging cable sample in GC/MS.
- Publication Part Number: 5994-7215EN
- Created: 18 Mar 2024
- 429 KB
Examination of Mass Spectra of Aroma Components in Essential Oils via GC/MS by using HydroInert Ion Source Specifically for Use with Hydrogen as a Carrier Gas
- Publication Part Number: 5994-5818EN
- Created: 06 Feb 2024
- 1 MB
This application demonstrates that hydrogen carrier gas, when paired with the Agilent HydroInert source, is a viable option for the analysis of terpenes in cannabis flower.
- Publication Part Number: 5994-7040EN
- Created: 09 Jan 2024
- 578 KB
This application note demonstrates residual solvents analysis (RSA) using headspace as a sample introduction technique on a single quadrupole GC/MS in selective ion monitoring (SIM) mode with hydrogen as the GC carrier gas.
- Publication Part Number: 5994-7034EN
- Created: 01 Jan 2024
- 7 MB
This application note outlines the translation of a GC/MS forensic drug screening method from using helium to hydrogen carrier gas by applying the HydroInert source.
- Publication Part Number: 5994-6982EN
- Created: 20 Dec 2023
- 2 MB
This study investigates how the 5Q series of columns impact the performance and durability of the HydroInert source tune.
- Publication Part Number: ASMS 2025 Poster MP 358
- Created: 15 May 2025
- 365 KB
This manual contains information for operating and maintaining the Agilent JetClean System.
- Publication Part Number: G7077-92052
- Created: 01 Oct 2024
- 2 MB
This manual contains information for operating and maintaining the Agilent JetClean System.
- Publication Part Number: G7077-93052
- Created: 01 Oct 2024
- 2 MB
This manual contains information for operating and maintaining the Agilent JetClean System.
- Publication Part Number: G7077-98052
- Created: 01 Oct 2024
- 2 MB
This manual contains information for operating and maintaining the Agilent JetClean System.
- Publication Part Number: G7077-96052
- Created: 01 Oct 2024
- 2 MB
This manual contains information for operating and maintaining the Agilent JetClean System.
- Publication Part Number: G7077-94052
- Created: 01 Oct 2024
- 2 MB
This manual contains information for operating and maintaining the Agilent JetClean System.
- Publication Part Number: G7077-97052
- Created: 01 Oct 2024
- 2 MB
This manual contains information for operating and maintaining the Agilent JetClean System.
- Publication Part Number: G7077-95052
- Created: 01 Oct 2024
- 2 MB
This manual contains information for operating and maintaining the Agilent JetClean System.
- Publication Part Number: G7077-99052
- Created: 01 Oct 2024
- 2 MB